Launch offer — valid today only

📄 Digital book in PDF · read it on your phone or print it

The Industrial Electrician Exam and the CEC in Drawings One Topic per Page, Every Calculation in the Same Steps

Single-line diagrams, transformers, 9-lead motors, overloads, ladder logic, VFDs, the PLC scan, 4-20 mA loops and lockout. Each topic has its own page: the drawing first, then what you need to remember. 63 illustrated pages.

START STUDYING THIS WAY

🔒 Secure checkout · PDF by email · 30-day guarantee

Every topic, its own pageEach circuit and calculation drawn, with the explanation right beside it
63 illustrated pages63 illustrated pages in 8 parts, from Ohm's law to your last-week plan
Up-to-date sourcesCEC Part I (CSA C22.1), the Red Seal Occupational Standard and CSA Z460
PDF by emailFormat

Look Inside the Book

Every page has one big drawing and a box with the numbers, rules and steps you need to know:

CT 600:5 = 120:1, 5 A secondary, and never open it under load
CT 600:5 = 120:1, 5 A secondary, and never open it under load
40 A motor: conductors ≥ 50 A; overload ≤ 50 A (SF 1.15) or ≤ 46 A
40 A motor: conductors ≥ 50 A; overload ≤ 50 A (SF 1.15) or ≤ 46 A
Disconnect, fuses, contactor, overload: the overload protects the motor, the fuses protect the circuit
Disconnect, fuses, contactor, overload: the overload protects the motor, the fuses protect the circuit
0-150 °C transmitter at 10 mA = 56.25 °C · 12 mA = 50%
0-150 °C transmitter at 10 mA = 56.25 °C · 12 mA = 50%
Ampacity: Tables 1–4, then Table 5A for heat, Table 5C for bundling, Rule 4-006 for terminals.
Ampacity: Tables 1–4, then Table 5A for heat, Table 5C for bundling, Rule 4-006 for terminals.
Lockout per CSA Z460-20: nine typical steps, stored energy released, verified live-dead-live.
Lockout per CSA Z460-20: nine typical steps, stored energy released, verified live-dead-live.
Ohm, power, voltage drop, impedance, PF, three-phase, transformers, motor speed, slip, V/Hz and 4-20 mA: one sheet.
Ohm, power, voltage drop, impedance, PF, three-phase, transformers, motor speed, slip, V/Hz and 4-20 mA: one sheet.
1800 r/min synchronous, 125% conductors, 115/125% overloads, wye-delta at about one-third.
1800 r/min synchronous, 125% conductors, 115/125% overloads, wye-delta at about one-third.

Swipe to see more →

These are real pages from the book. The table of contents is the full one: 8 parts and 59 topics.

The Problem Isn't You. It's How It Was Explained to You.

A practice question gives you a 40 A motor on the nameplate and asks for the conductor size and the overload limit. You know the motor. The percentages won't line up.

The course manual covers it in paragraphs of rules and cross-references: conductors in one place, overloads in another, service factor tucked into a sentence at the end. Read that way, 125 and 115 blur into one number.

Disconnect, fuses, contactor, overload: the overload protects the motor, the fuses protect the circuit

In the book, that same motor is one page. The 40 A goes in and two arrows come out: conductors at 125%, so at least 50 A; overload at 125% if the service factor is 1.15 or more or the marked temperature rise is 40 °C or less (up to 50 A), or 115% for any other motor (up to 46 A).

The rest of the exam works the same way: the plant single-line, 9-lead wye connections, 4-20 mA scaling, conductor ampacity and lockout each get their own page.

So when the next motor comes up, on the exam or on the floor, you run the same steps and get the answer without opening the manual.

COMPARE FOR YOURSELF

The Same Topic, Two Ways to Study It

THIS
  • The manual: line after line of text
  • Lead connections described only in words
  • You walk into the exam still unsure
A nine-lead, wye-connected dual-voltage motor has two windings per phase, terminated as T1 through T9. For operation at the lower rated voltage, the windings of each phase are connected in parallel: T4, T5 and T6 are joined to form a second star point, and T1-T7, T2-T8 and T3-T9 are connected to L1, L2 and L3 respectively. For the higher rated voltage, the windings are connected in series by joining T4 to T7, T5 to T8 and T6 to T9, with the supply applied to T1, T2 and T3.
FOR THIS
  • The 9-lead motor in one drawing
  • Low and high voltage joins in a box
  • You see it and you get it
40 A motor: conductors ≥ 50 A; overload ≤ 50 A (SF 1.15) or ≤ 46 A
CONTENTS

Take a Look at the 8 Parts and 59 Topics

Basics, AC and three-phase, plant distribution and transformers, motors and starters, control circuits and ladder diagrams, drives, PLCs and instrumentation, code, grounding and safety, and exam review: 63 pages, all illustrated

IBack to Basics, Drawn · pp. 5-11
  1. How the Exam Is Built
  2. Ohm's Law Triangle in One Picture
  3. The Power Wheel: Watts Without Guessing
  4. Series, Parallel, Combination: Same 3 Steps
  5. Kirchhoff's Two Laws on a Real Circuit
  6. Magnetism and Induction: Why Coils Push Back
  7. Capacitors and Inductors: Who Leads, Who Lags
IIAC and Three-Phase · pp. 12-18
  1. The Sine Wave: Peak, RMS, Frequency
  2. Impedance and the Impedance Triangle
  3. Power Factor: The Beer Glass Picture
  4. Correcting Power Factor in 4 Steps
  5. Three-Phase: Three Waves 120° Apart
  6. Wye vs Delta: Line and Phase Values
  7. Three-Phase Power in the Same 3 Steps
IIIPlant Distribution and Transformers · pp. 19-25
  1. The Plant Single-Line: Utility to Machine
  2. Transformer Ratio Without Mixing It Up
  3. Sizing a Transformer by kVA
  4. Three-Phase Connections: Delta-Wye and Friends
  5. Transformer Polarity and Paralleling
  6. Instrument Transformers: CT and PT
  7. Protection Coordination in One Curve
IVMotors and Starters · pp. 26-33
  1. How a 3-Phase Induction Motor Turns
  2. Reading a Motor Nameplate
  3. Dual-Voltage Leads: 9-Lead Wye and Delta
  4. Motor Conductors and Overloads per the CEC
  5. Across-the-Line Starter: Power and Control
  6. Reduced-Voltage Starting Compared
  7. Reversing and Two-Speed Starters
  8. Synchronous, DC and Single-Phase Motors
VControl Circuits and Ladder Diagrams · pp. 34-40
  1. Reading a Ladder Diagram: Rules of the Rungs
  2. Symbols You Must Know Cold
  3. Stop-Start-Seal-In, Step by Step
  4. Multiple Stations and Interlocks
  5. Timers: On-Delay vs Off-Delay
  6. Control Transformers and Fusing
  7. Troubleshooting a Control Circuit: Half-Splitting
VIDrives, PLCs and Instrumentation · pp. 41-48
  1. Inside a VFD: Rectifier, DC Bus, Inverter
  2. Volts per Hertz and Speed Control
  3. VFD Faults and Good Practice
  4. The PLC Scan: Read, Solve, Write
  5. PLC I/O: Discrete, Analog, Sinking, Sourcing
  6. Ladder Logic in the PLC: XIC, XIO, OTE
  7. Timers and Counters in PLC Logic
  8. 4-20 mA Loops and Scaling
VIICode, Grounding and Safety · pp. 49-56
  1. How the CEC Is Organized
  2. Conductor Ampacity and Correction
  3. Voltage Drop in 4 Steps
  4. Grounding vs Bonding
  5. Ungrounded and High-Resistance Grounded Systems
  6. Hazardous Locations: Zones Made Visual
  7. Lockout and Verification
  8. Arc Flash and Shock Boundaries
VIIIExam Review and Practice · pp. 57-63
  1. The Calculation Formula Sheet
  2. Single-Line and Ladder Symbols Recap
  3. Wye, Delta and Transformer Recap
  4. Motor and Starter Recap
  5. Troubleshooting Flow: Symptom to Cause
  6. How to Read a Multiple-Choice Question
  7. Your Last-Week Review Plan

One Page, One Topic, All Clear

Think of it this way:

Night shift, a conveyor motor gets swapped and the lead wants to know if it's wired for the right voltage. You open the junction box and see nine leads.

In the book, you open the 9-lead motor page and both connections are drawn side by side: low voltage with 4-5-6 joined, high voltage with 4–7, 5–8 and 6–9 joined, and the lines landing on 1, 2 and 3.

Ampacity: Tables 1–4, then Table 5A for heat, Table 5C for bundling, Rule 4-006 for terminals.

Same with the plant single-line, motor overloads, 4-20 mA scaling, lockout and the PLC scan: each one on its own page.

Industrial Electrician Exam Illustrated is 8 parts and 59 topics, all drawn, and it finishes with a formula sheet, symbol and motor recaps, a troubleshooting flow and a last-week review plan.

What you see drawn, you don't have to memorize.

What's Inside Industrial Electrician Exam Illustrated:

Ipp. 5-11

Back to Basics, Drawn

How the exam is built, Ohm's law, the power wheel, series and parallel circuits, Kirchhoff, magnetism, capacitors and inductors.

IIpp. 12-18

AC and Three-Phase

The sine wave, impedance, power factor and how to correct it, three-phase, wye vs delta and three-phase power in the same 3 steps.

IIIpp. 19-25

Plant Distribution and Transformers

The plant single-line from utility to machine, transformer ratio and kVA sizing, three-phase connections, polarity, CTs and PTs, and protection coordination.

IVpp. 26-33

Motors and Starters

How the induction motor turns, nameplates, 9-lead connections, conductors and overloads, across-the-line, reduced-voltage, reversing and two-speed starters, and other motor types.

Vpp. 34-40

Control Circuits and Ladder Diagrams

Rules of the rungs, the symbols to know cold, stop-start-seal-in, multiple stations and interlocks, timers, control transformers and half-splitting.

VIpp. 41-48

Drives, PLCs and Instrumentation

Inside a VFD, volts per hertz, drive faults, the PLC scan, I/O, XIC-XIO-OTE, timers and counters, and 4-20 mA scaling.

VIIpp. 49-56

Code, Grounding and Safety

How the CEC is laid out, so you find the rule fast. Then ampacity and correction, voltage drop in 4 steps, grounding vs bonding, HRG systems, hazardous locations, lockout and arc flash, each one drawn.

VIIIpp. 57-63

Exam Review and Practice

The formula sheet, symbol, transformer and motor recaps, the troubleshooting flow, how to read a multiple-choice question and your last-week plan.

At the end of the book: A one-page calculation formula sheet, symbol and motor recaps, a troubleshooting flow and a last-week review plan.

Plus: 2 Free Books

Exam-Style Practice Questions with Answers

BONUS 1: «Exam-Style Practice Questions with Answers»

Value on its own: US$ 17.90

Practise with multiple-choice questions in the style of the journeyperson exam, each with the answer explained, so you know where you stand before exam day.

15 Common Mistakes: Before & After

BONUS 2: «15 Common Mistakes: Before & After»

Value on its own: US$ 14.90

See the 15 most frequent errors in diagrams, calculations and control circuits drawn side by side with the correct version, so you don't repeat them on the exam or on the floor.

Industrial Electrician Exam Illustrated with 2 Free Books

  • Industrial Electrician Exam Illustrated: 63 illustrated pagesUS$ 63
  • BONUS 1: Exam-Style Practice Questions with AnswersUS$ 17.90
  • BONUS 2: 15 Common Mistakes: Before & AfterUS$ 14.90
  • High-resolution PDF to printIncluded
Total value US$ 95.80
YOUR PRICE:
US$ 27
You save US$ 68.80
YES, I WANT INDUSTRIAL ELECTRICIAN EXAM ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

Secure purchaseEncrypted payment30-day guarantee

PDF by email: We email you Industrial Electrician Exam Illustrated as a PDF, together with the two free books. It's a single payment: no installments, no extra charges.

Who This Book Is For

You're in your final apprenticeship period

You're in your final apprenticeship period

Every topic from your in-school blocks, put back in order and drawn, so you can review between shifts instead of digging through binders.

Your exam date is booked

Your exam date is booked

The calculations always in the same steps, the formula sheet and the recaps on one page each, so the last weeks are review, not catch-up.

You already work the plant floor

You already work the plant floor

You know the work. The book puts the theory behind it in order, so you can challenge the exam and explain why the circuit does what it does.

Everything You Get Today

US$ 95.80US$ 27
YES, I WANT INDUSTRIAL ELECTRICIAN EXAM ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

30DAYS
GUARANTEE

30-Day Guarantee

Try Industrial Electrician Exam Illustrated for 30 days, bonus books included.

We refund everything if the file won't open, if the book isn't what you see here, if you were charged twice or if the email doesn't arrive. Just email us.

You pay once. No subscriptions.

Frequently Asked Questions

Is it for me if I've worked in a plant for years and haven't studied in a long time?

Yes. It isn't a beginner's course: Part I is a quick, drawn refresher of the basics, and from there it goes straight into transformers, motors, controls, drives, PLCs and code calculations, one topic per page.

Where does the content come from?

It's checked against the current Canadian Electrical Code, Part I (CSA C22.1), the Red Seal Occupational Standard for Industrial Electrician, CSA Z462 and CSA Z460. Code rules are explained with our own examples, in the units the code uses (AWG and kcmil, metres, °C); no code text or tables are reproduced. Provinces adopt the CEC with their own amendments, so confirm exam details with your provincial or territorial apprenticeship authority.

Is it official material?

No. It's an independent illustrated study book. It isn't issued, approved or endorsed by the Red Seal Program, CSA Group or any apprenticeship authority, and it doesn't give a certificate or count toward your hours or in-school training.

Does it replace my course or training?

No. It's a review tool to use alongside your technical training, your on-the-job hours and the code book itself. What it adds: the topics your binders and videos cover, put in one order, one drawn page each, with the numbers in a box, so you can review a topic in a few minutes instead of hunting through notes.

Are the practice questions the real exam questions?

No. They're written for this book, in the style of a multiple-choice journeyperson exam, each with the answer explained.

When and how do I get it?

The book and the 2 bonus books arrive as PDFs by email, at the address you enter at checkout.

Do I have to pay every month?

No. It's a one-time payment. No subscription.

Can I have it on paper?

Yes. The PDF is printable, so you can print the whole book or just the pages you want to keep in your toolbox.

How does the refund work?

You have 30 days. We refund everything if the file won't open, if the book isn't what you see on this page, if you were charged twice or if the email doesn't arrive: just email us.

Before You Close This Page

No more rereading with nothing sticking.

The 9-lead motor connections: you see them drawn and that's it.

You walk into the exam knowing where everything is.

Drawings make studying faster.

The book is right below.

One-time payment: US$ 27 · Guarantee: 30 days · PDF by email

YES, I WANT INDUSTRIAL ELECTRICIAN EXAM ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.